Skip to main content
Feature
January 9, 2025

Exceeding minimum code requirements can maximize savings

JHU APL Buillding 28 28129 itoke7h0kh WX
Listen to this story
AI powered reader
/

Capital projects require significant investments in money and time. When the budget is tight—almost always the case—the idea of approving a building design that exceeds the minimum required energy performance can seem imprudent. Still, leading companies and institutions are taking bold actions that benefit the environment and society as a whole.

Buildings contribute approximately 40% of global carbon emissions, a major cause of climate change.1 Across the U.S., most jurisdictions have set minimum performance requirements for construction projects that are based on model energy codes, namely the International Energy Conservation Code (IECC) and ASHRAE 90.1 Energy Standard. Some states, like California, have developed their own standard. Both the IECC and ASHRAE 90.1 are updated every three years to reflect ongoing advancements in building science and targets.

JHU APL Buillding 28 2
A rendering of the future Johns Hopkins University Applied Physics Laboratory Building 28.

“The energy code is one of the most cost-effective ways to deliver on higher performing buildings,” says Page Building Performance Director Justin Shultz. “Its benefits include pushing us all together in the right direction.” That direction leads to net-zero energy, where buildings generate only as much greenhouse gas as they can remove from the atmosphere or offset with clean technologies to minimize the exacerbation of climate change.

Still, says Jacob Stieb, Senior Building Performance Analyst at Page, “you don’t have to use the latest technology or materials on most projects to meet code.”

Owner initiative

Since 1975, the U.S. Department of Energy (DOE) has calculated the expected building efficiency improvement with every model energy code update.2 A project meeting ASHRAE 90.1-2022,3 for instance, should deliver a nearly 10% improvement in site energy, source energy, energy cost, and carbon emissions savings over one designed to the standard’s 2019 predecessor.4 The energy code or standard your project must meet depends on its jurisdiction. Though the DOE has provided federal funding to help jurisdictions transition to more modern standards, some states and cities continue to administer decades-old standards—if they require one at all.

As a result, owners have the greatest say on the extent to which their projects will minimize their carbon emissions. “Historically, some market sectors, like the federal buildings, try to lead the pack and require standards that exceed the energy code,” Stieb says. “Likewise, many academic projects are net-zero energy ready and are able to accept photovoltaic panels. But for the most part, projects are very dependent on the client.”

Cost-benefit of beating the baseline

“Surpassing your jurisdiction’s energy code or standard does more than get your organization a step closer to net zero,” Shultz says. “There’s tremendous benefit in the goodwill and environmental stewardship it demonstrates to the community.”

The next question your organization will likely ask is, “How much does it cost?” A recent Pacific Northwest National Laboratory study found immediate payback for an array of project types designed to ASHRAE 90.1-2019 versus 90.1-2016, based on a simple payback model.5 When analyzing data aggregated over a range of building types and climate zones, PNNL found a 90.1-2019 project would generate a net saving of $4.12 per square foot over a 30-year life cycle.

Commercial real estate companies have also observed higher lease premiums and occupancy rates for projects certified by the U.S. Green Building Council’s LEED rating system. In 2021, Cushman & Wakefield calculated a 25.3% per square foot premium for LEED-certified Class A offices in urban centers and a 40.9% premium in the suburbs.6

Page’s engineering team is increasingly modeling the expected energy performance of its project designs for clients. “We’ll conduct a life cycle cost analysis to look at the total cost of ownership associated with different design scenarios,” Shultz says. “For instance, the cost of a more efficient system may have a premium today, but over the next 15 to 30 years of the building’s operation, it will save an owner millions of dollars.”

Screenshot202025 01 2320at205 03 0120 PM
Figure 1: 40-Year Life Cycle Cost Analysis of Air-Cooled vs. Water-Cooled Chillers. Despite a $2.5 million premium in first and maintenance costs, the 10% annual energy savings generated $5.1 million in operational savings, resulting in a net $2.6 million life-cycle cost savings.

People benefit as well

Occupant comfort is highly dependent on a building’s HVAC systems. Over time, energy codes and standards have raised requirements for building envelope tightness, thermal bridging, and mechanical system performance. According to the DOE’s Building Energy Codes Program, the HVAC system in a large office building designed to ASHRAE 90.1-2022 would use 29% less energy than its 90.1-2007 counterpart; for medium and small buildings, the savings jump to 46% and 43%.7 “It’s simply good design to choose mechanical systems that are a little more efficient than the previous project you designed,” Shultz says.

The increase in occupant comfort stemming from these improvements can lead to significant financial savings unrelated to energy bills. A study published in Journal of Building and Environment in 2022 found that occupants of WELL-certified buildings report a 10-point increase in median productivity and a 30% increase in overall workplace satisfaction, which can mean less attrition.8

Going with a higher-performance HVAC system can also mean the downsizing of other building systems due to the reduced heating and cooling load, Stieb notes. “When you have an integrated, whole building design, you can save on mechanical systems, which trickles down to your electrical sizing,” he says. “Now you can have smaller, less expensive mechanical and electrical equipment and components, such as conduit. You can end up saving more than we predict.”

Case study in point

Large scale projects require thoughtful and deliberate consideration of energy performance and Building 28 at the Johns Hopkins Applied Physics Laboratory (JHU APL) exemplifies how surpassing standard energy codes can return economic and environmental benefits. This 400,000-square-foot science and technology facility in Laurel, Maryland is designed to accommodate the laboratory's expanding workforce and evolving programmatic needs. It will feature electronic laboratories, a 3-megawatt data center, office spaces, food services, and conferencing areas.

Screenshot202025 01 2320at205 03 1620 PM
Figure 2. Comparison of Energy Code Baseline to the Proposed Design of the Johns Hopkins University Applied Physics Laboratory Building 28.

By integrating Building Performance Analysis (BPA) at every stage, the project team evaluated energy conversation measures (ECMs) to optimize daylighting, energy use intensity (EUI) and mechanical system performance. Early in the design analysis stage, the Page team explored four building masses, three envelope configurations, and their impacts on solar potential, heat gain and occupant comfort, resulting in a high-performance building envelope with U-values of 0.027 for the roof, and 0.053 for the walls - improvements of over 15%.

Advanced mechanical systems, including dedicated outdoor air systems (DOAS) with total enthalpy heat recovery wheels paired with high-efficiency chillers serving chilled beams significantly improved energy performance. These upgrades, combined with multiple chilled water temperature configurations and all electric boilers, achieved a two-year payback period while supporting efficiency gains. In total, the project delivered 21.9% energy savings across lighting, heating, cooling, and fan systems and a remarkable 47.1% decrease in regulated loads, far exceeding energy code requirements.

As a result, Building 28 secured a $1,000,000 incentive through the Empower Maryland program. It also demonstrated how integrated design and performance strategies can drive long-term environmental and economic benefits, quantifying the value of going beyond energy codes.

Contributors

Justin has a passion for problem-solving. Working alongside his design colleagues, Justin uses computational analysis to answer our most pressing sustainable design questions. In his role, he partners with clients and design teams to set bold sustainability goals and map out clear, effective strategies to achieve them. He provides performance-based recommendations through climate, building energy, building envelope, daylighting, computational fluid dynamics analyses, and more. With a Ph.D. in Arch. Sci. and a certificate in Building Energy Modeling, understanding complex problems and providing simple solutions has defined Justin’s career.

Jacob is a former NCAA Division I swimmer and Eagle Scout, grounded in discipline, perseverance, and technical excellence. He credits his athletic experience with shaping the focus and resilience that fuel his career. Jacob focuses on energy modeling and optimizing systems for high-performance, sustainable design with a specialization in data centers and semiconductor wafer fabrication plants. Jacob also provides IES-VE training and support, helping engineers develop energy-efficient solutions. Driven by a passion for mentorship and lifelong learning, he’s committed to advancing both people and projects toward a more sustainable future.

1014063 01 N191 Retouched

Talk with us

Complex challenges need fresh perspectives and deep expertise. Connect with our team to explore how we can help you create spaces that make a real difference.